hayward blue essence troubleshooting

Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. Is the pump pot filling full of water, or does it ever catch prime fully? Diagrams, Pool After just a few minutes the flow slows down to almost nothing. Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. Water level is good, changed basket lid seal, all unions are tight. The pump top is under suction, not pressure (like the filter). The Hayward swim profilter is making a loud noise and the top vibtrates. We cannot get it going again. Theory and practice | Find, read and cite all the research you need on ResearchGate Fitness View More. Inspect the motor shaft for any obstructions. . Hi James, for a two speed motor, I would suggest the run capacitor, but not sure if the VS motor has one? It did not do this until we pressure washer the deck and some wood chips got into the pool. A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. Juat replaced motor. Pumps need 120V, +/- 10%, so maybe the voltage is fluctuating, from loose connection from breaker to outlet, or a loose breaker. After filter was fully re-assembled- pump would turn on. I dont want to over tighten it. Air leaks can occur over time, the most often areas are a loose pump lid, unlubed pump lid oring, or my favorite, the loose threaded fitting that brings water into the pump. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. "primaryImageOfPage": {
There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. 5. low water level or skimmer weir blocking water flow I have no pressure on my filter. Pump is sitting about 3 feet below level of water in pool..maybe a bit more. When running through all these checks and balances if it is noticed that there is not bond wire or that the tightening screws are not all secure, correct the issue. If you get no response from your Hayward pool pump when you flip the switch, first verify the terminal board connections match the wiring diagram on the motor data plate label. Well, you first need to inspect it, and if the parts are broken, replace them. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Aquarite is not powering up at all. Thanks for your time. Now if none of that advice helps, and you still cannot get the lid to go on, or seal up, I would suspect that either the lid or the housing is warped from an overheating situation, running for long periods of time without water flowing through it. If it blows again then I guess youll have to replace the pump body, which is usually about $100-200 cheaper than the cost of the whole pump. If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. I have a Hayward E40, After I vacuum the pool I see that I have D.E on the bottom again after two days or so. Today everything was running well and than at some point the hose that takes the water to the filter came loose from the pump. Hi Joe, make sure that the pump shaft is spinning freely. The loud noise could be the bearings, or it could be the impeller having come off the shaft and contacting the volute if you have an older bronze or brass pump, with an impeller that uses a stub shaft. JavaScript is disabled. Still have Drive error, heatsync overheated and day of weekflashing back and forth between the two. It is usually set to run at high rpm early morning and that is before sun hits it. When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. Or a loose base part rattling? Did you figure out your problem? Only half of my cell gets clogged up and the other half stays clean. Thank you. It makes humming sound 1-2 times before starting. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the Following this procedure will identify Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. "keywords": "",
Do you know what the suggested torque is for the housing cap screws? If you have an electric motor repair shop in town, they may have it in stock, or order it online. Worn bearings can also create enough heat to trip the switch. If the pump is on high when it is supposed to come on the pump motor humms and cuts off. Perflex filters can clog up with heavy oils, or not enough DE powder, or if undersized for the pool (just like any other filter), so it could be the filter yes. When I went out to drain water from the pool it wouldnt turn on. i removed the filter fingers and cleaned numerous times. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. Hi Lo in checking the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, it suggests bypassing the timeclock and wiring direct to the breaker. Any suggestions what it could be. No moisture. Greetings! Hello. Fitness View More. Hi it could be small wood chips stuck in the pump impeller. Or, soak them in a TSP solution (1 lb of TSP in 5 gals warm water), followed by a soaking in an acid solution, 1 gallon acid added to 4 gallons of water. Hi, yes shaft seal failure. 2. pump lid gasket or o-ring not lubed, or not positioned properly (superpump) Still no luck. This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. Hope that helps! Hi, Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. View Details Usfitnessfinder.com. Just opened my in ground pool went to turn the pump on and nothing. check that everything is tight and aligned. 2 year warranty. A spike below 100V or above 140V, could blow a capacitor. Hopefully it has a switch inside the pump so I can change it for 115. What you have to do is drain the filter and remove all those tiny bolts, and pull out the entire nest assembly. Stackable Rose Gold Wedding Bands, Hi Dave, check that the centrifugal switch is screwed on tightly to the end of the motor shaft. If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. If the shaft spins freely, no rust problem. Or switch to Pentair, but I wouldnt say theyre better your case is unusual, the pump may have been dropped, suffered some hard knock from a tree branch, or perhaps it had a defective bearing to begin with. Thanks, good question. Step 3: Double check the wires on the flow switch for damage. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. If you have other questions, you can email me Davy, at swimmers@intheswim.com. I figure bearing, I pulled the motor off the housing and cleaned a few pine needles out of impeller but nothing else.Its only 2 years old,I take really good care of the equipment so Im surprised. Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. (GFI 240V 20amp) Just started getting a No Flow error. Perhaps you can replace it with a 20 amp breaker, of the same manufacturer, and youd be all set, or move some of the other devices to draw power from a different breaker. You can also check that the phone cord wire is plugged into the interface, on underside. Power going in, but power not coming out and therein lies the problem, which could just be a loose wire, broken wire or faulty resistor/capacitor/relay. We opened the pool a few weeks back with no pump motor problems. Using a Slime Bag, attached to the pool return, to act as a secondary filter, would be a solution. Remove the two wires connected to the capacitor, with a small flathead, or needle nose pliers. I will try that tonight. Hi Davy, I have a Hayward Super II which has been running well for years. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. We have a circuit board that controls these two motors as well as an LED light. Any advice?? Packing Pool Putty or Silicone around the fitting is a good fix, replacing the fitting is a better fix. Some advice? If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. I have an older Haywood super pump 3/4 hp, i replaced it with a new 3/4 hp motor. Then the others are 2-high speed and 1-low speed wire see the diagram on this page: http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html. Is there something on the board I need to change? Could the filter be plumbed backwards possibly? First inspect wiring, to be sure everything is tight and secure, and there are no loose wires, or anything that looks wrong back there. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I am getting 24VAC from top Rectifier to PCB Input, says it should be 12VAC. I have taken it apart and put it back together probably 5-6 times looking for internal issues. My issue is that the normal operating pressure is around 13-15 psi. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. Hi Pat, good question you can continue to use the IG pump, no problem. If you are getting correct voltage into the rear of the motor (120V or 240V, +/- 10%), but still the motor makes no noise at all, its likely DOA the motor at least. News Reporter Reveals On Live TV That Shes Been Secretly Recording . Is my pool pump dead? If there's one thing for certain about pool equipment, is that they will all break down at some point in time. Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. The cap is located at 9 oclock in the rear of the motor, when they go bad, they sometimes bulge or crack, or turn brown or smell strongly of burnt wires They are cheap to replace, worth a shot, replace with identical MFD number. 6. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. New motor sounds like the thermal overload switch (located at 12 oclock in the rear of the motor) is shutting off the motor, which is usually not a good sign, and mostly means the pump is on its way out. Hi Tommy, very loud pump could be that the pump overheated, because it lost prime, and this either damaged the shaft bearings or melted/warped the impeller and diffuser. "width": "611",
Yes, pool heaters do have a minimum flow requirement. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. put in a new motor and had the old motor repaired. https://www.instagram.com/inyopools/JOIN our circle on GOOGLE+ https://plus.google.com/+Inyopools/postsAs with any automatic salt chlorine generator, tune ups are needed from time to time. Hi, could be that the capacitor has worn out. 2. check the pump motor wiring, at the timeclock and the motor. What is happening is that the pump pulls so hard that either an air leak around the pump develops, or the vacuum hose or pool to pump hose begins to crimp and collapse. Im not sure how the filters went bad being winterized, but they were way old. "name": "In The Swim",
When I flip a switch to manually turn on to high speed, it does not work it is still working at low speed. Inspect wiring for any loose or corroded connections. Hi, we just installed a new AquaRite unit and it has been running for 48 hrs The salt level is 3100 ppm (pool store also confirmed and tested the water, no issues detected with the water). The original pump (assy A) smells burnt. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. The cord does feel warm to the touch. Hi there, 30 psi is pretty high pressure, sounds like the pump is having trouble pushing thru are you using enough DE powder? Try again? It worked great for the season. Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. The motor model # is C48L2N134B1. Once it finishes calibrating, cycle the main switch from AUTO to SUPER CHLORINATE and back to AUTO. Just replaced my old Polaris booster pump, 3/4 hp, with a 1hp pump. It worked fine just prior to a filter cleaning. If it makes no noise at all, that is often a loose wire or no power. A closed valve, or plugs in the pool wall? I have been able to spin the motor shaft. Turn on heater and see if you can narrow down the noise. Nick, it could be the capacitor, I guess water got on the terminal board, to trip the breaker. Troubleshooting Guides | Support Center - Hayward Pool Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). Pull the motor out of the pump and turn it on briefly, to see if the noise remains. If they are within range, replace the drive. Question. Shut off power at the breaker to all pool equipment Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE then back to AUTO. }
. The pump never turns off but it should pull the water through constantly. Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. died and I put in the old repaired motor. switch in the center. I remplace it and now the sistem works!! Hi Bryan, not normal but not uncommon. This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Also, using Teflon pool lube on the pump lid oring should help. Look closely at the centrifugal switch in the middle/center/end of shaft, make sure its tight and intact. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. Thank you. In some instances, it could just be a bad breaker. Also check other wires in the back of the motor. Or maybe the glue that Im assuming is no longer working? My pool pump was running fine until I turned it off. We would like to show you a description here but the site wont allow us. 6. Is that correct or does one go on the nut? Features: Replacement for Hayward T-CELL-5, GLX-CELL-5-W and Aqua Trol Suitable for pools up to 20,000 gallons Comes with a 15 foot cord Clear housing for visual inspection of cell No need for re-plumbing, direct fitting threads Meets all original factory specifications Reverses polarity to automatically clean cell Click here to shop our store. For Use With: Hayward AquaTrol Pool Chlorine Generator Brand: HAYWARD REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. The Tristar VS would be a good choice and easy to plumb, since its the same pump. Look for insect infestation. Hi Davy, Have a brand new Hayward power flo LX. Went to start the pump to prep the pool for the kids and sill attempt to turn on but then stops. Then back to no pressure. Now what? Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. Can you help me with this problem Robert, Hi Robert, I dont see an error code 11 in the owners manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true start by making sure that the filter is clean, the valves are open, and the pump lid is on tight. Read up on it and seems it happens a lot and the motor drive needs to be replaced. You can only compare 4 products at a time. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. Although in low speed, chlorine is not generated so not sure why even run the low speed. "publisher": {
Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. Any tips? Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. could be cord problem, too. Suggestions on what to do next. Is this rare? if it does not come back on, check switches, turn breaker all the way off and back on again. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. This is actually the second motor in 6 months. Hello , This is an inactive thread.